Sunday, November 15, 2020

ACTIVATED SLUDGE PROCESS - The activated sludge process was discovered in 1913 in the UK by two engineers, Edward Arden and W.T. Lockett, conducting research for the Manchester Corporation Rivers Department at Davyhulme Sewage Works. Experiments on treating sewage in a draw-and-fill reactor (the precursor to today's sequencing batch reactor) produced a highly treated effluent. Believing that the sludge had been activated (in a similar manner to activated carbon) the process was named activated sludge. Not until much later was it realized that what had actually occurred was a means to concentrate biological organisms, decoupling the liquid retention time (ideally, low, for a compact treatment system) from the solids retention time (ideally, fairly high, for an effluent low in BOD5 and ammonia.) Activated sludge (AS) is a process dealing with the treatment of sewage and industrial wastewaters. Atmospheric air or in rare cases pure oxygen is introduced to a mixture of primary treated or screened sewage (or industrial wastewater) combined with organisms to develop a biological floc ("Activated Sludge" AS). The mixture of raw sewage (or industrial wastewater) and biological mass is commonly known as Mixed Liquor. With all activated sludge plants, the concentration of biodegradable components present in the influent is reduced due to biological (and sometimes chemical) processes in the aeration tank.

..........................................................................................................................................................................................................................................................................................................

Activated Sludge Process

IWA Publishing 


 

Activated sludge (AS) is a process dealing with the treatment of sewage and industrial wastewaters and developed around 1912-1914.

o  There is a large variety of design, however, in principle all AS consist of three main components: an aeration tank, which serves as bio reactor;

o  a settling tank ("final clarifier") for separation of AS solids and treated waste water;

o  a return activated sludge (RAS) equipment to transfer settled AS from the clarifier to the influent of the aeration tank (Fig. 1).

Atmospheric air or in rare cases pure oxygen is introduced to a mixture of primary treated or screened sewage (or industrial wastewater) combined with organisms to develop a biological floc ("Activated Sludge" AS).

The mixture of raw sewage (or industrial wastewater) and biological mass is commonly known as Mixed Liquor.

Typically, dry solids concentrations of mixed liquor (MLSS) range from 3 to 6 g/L.

With all activated sludge plants, the concentration of biodegradable components present in the influent is reduced due to biological (and sometimes chemical) processes in the aeration tank.

The removal efficiency is controlled by different boundary conditions, e.g. the hydraulic residence time (HRT) in the aeration tank, which is defined by aeration tank volume divided by the flow rate.

Other factors are: Influent load (BOD5, COD, Nitrogen,...) in relation to the AS solids present in the aeration tank (Food:Microorganism Ratio, F:M Ratio), oxygen supply, temperature, etc.

At the effluent of the aeration tank, mixed liquor is discharged into settling tanks and the supernatant (treated waste water) is run off to be discharged to a natural water or undergo further treatment before discharge.

The settled AS is returned to the head of the aeration tank (RAS) to re-seed the new sewage (or industrial wastewater) entering the tank and to ensure the desired MLSS concentration in the aeration tank.

Due to biological growth (and solids present in the raw waste water which are only partly degraded), excess sludge eventually accumulates beyond the desired MLSS concentration in the aeration tank.

This amount of solid (called Waste Activated Sludge WAS) is removed from the treatment process to keep the ratio of biomass to food supplied (sewage or wastewater) in balance and the F:M ratio in a defined range.

WAS is stored away from the main treatment process in storage tanks and is further treated by digestion, either under anaerobic or aerobic conditions prior to disposal.

Activated Sludge Process

Figure1. The diagram of activated sludge process

Many sewage treatment plants use axial flow pumps to transfer nitrified mixed liquor from the aeration zone to the anoxic zone for de-nitrification.

These pumps are often referred to as Internal Mixed Liquor Recycle pumps (IMLR pumps).

The raw sewage, the RAS, and the nitrified mixed liquor are mixed by submersible mixers in the anoxic zones in order to achieve de-nitrification.

Purpose

In a sewage (or industrial wastewater) treatment plant, the activated sludge process can be used for one or several of the following purposes:

o  oxidizing carbonaceous matter: biological matter.

o  oxidizing nitrogeneous matter: mainly ammonium and nitrogen in biological materials.

o  removing phosphate.

o  driving off entrained gases carbon dioxide, ammonia, nitrogen, etc.

o  generating a biological floc that is easy to settle.

o  generating a liquor low in dissolved or suspended material

History

The activated sludge process was discovered in 1913 in the UK by two engineers, Edward Arden and W.T. Lockett, conducting research for the Manchester Corporation Rivers Department at Davyhulme Sewage Works.

Experiments on treating sewage in a draw-and-fill reactor (the precursor to today's sequencing batch reactor) produced a highly treated effluent.

Believing that the sludge had been activated (in a similar manner to activated carbon) the process was named activated sludge.

Not until much later was it realized that what had actually occurred was a means to concentrate biological organisms, decoupling the liquid retention time (ideally, low, for a compact treatment system) from the solids retention time (ideally, fairly high, for an effluent low in BOD5 and ammonia.)

Activated Sludge Process Variables

The main variables of activated sludge process are the mixing regime, loading rate, and the flow scheme.

Mixing Regime

Generally, two types of mixing regimes are of major interest in activated sludge process: plug flow and complete mixing.

In the first one, the regime is characterized by orderly flow of mixed liquor through the aeration tank with no element of mixed liquor overtaking or mixing with any other element.

There may be lateral mixing of mixed liquor but there must be no mixing along the path of flow. 

In complete mixing, the contents of aeration tank are well stirred and uniform throughout.

Thus, at steady state, the effluent from the aeration tank has the same composition as the aeration tank contents.

The type of mixing regime is very important as it affects

(1) oxygen transfer requirements in the aeration tank,

(2) susceptibility of biomass to shock loads,

(3) local environmental conditions in the aeration tank, and

(4) the kinetics governing the treatment process.

Flow Scheme

o  The flow scheme involves:

o  the pattern of sewage addition

o  the pattern of sludge return to the aeration tank and

o  the pattern of aeration.

Sewage addition may be at a single point at the inlet end or it may be at several points along the aeration tank.

The sludge return may be directly from the settling tank to the aeration tank or through a sludge reaeration tank.

Aeration may be at a uniform rate or it may be varied from the head of the aeration tank to its end.

Types of plants

There are a variety of types of activated sludge plants. These include:

Package plants

There are a wide range of other types of plants, often serving small communities or industrial plants that may use hybrid treatment processes often involving the use of aerobic sludge to treat the incoming sewage.

In such plants the primary settlement stage of treatment may be omitted. In these plants, a biotic floc is created which provides the required substrate.

Package plants are commonly variants of extended aeration, to promote the 'fit & forget' approach required for small communities without dedicated operational staff.

There are various standards to assist with their design.

Oxidation ditch

In some areas, where more land is available, sewage is treated in large round or oval ditches with one or more horizontal aerators typically called brush or disc aerators which drive the mixed liquor around the ditch and provide aeration.

These are oxidation ditches, often referred to by manufacturer's trade names such as Pasveer, Orbal, or Carrousel.

They have the advantage that they are relatively easy to maintain and are resilient to shock loads that often occur in smaller communities (i.e at breakfast time and in the evening).

Oxidation ditches are installed commonly as 'fit & forget' technology, with typical design parameters of a hydraulic retention time of 24-48 hours, and a sludge age of 12-20 days.

This compares with nitrifying activated sludge plants having a retention time of 8 hours, and a sludge age of 8-12 days.

Deep Shaft

Where land is in short supply sewage may be treated by injection of oxygen into a pressured return sludge stream which is injected into the base of a deep columnar tank buried in the ground.

Such shafts may be up to 100 m deep and are filled with sewage liquor.

As the sewage rises the oxygen forced into solution by the pressure at the base of the shaft breaks out as molecular oxygen providing a highly efficient source of oxygen for the activated sludge biota.

The rising oxygen and injected return sludge provide the physical mechanism for mixing of the sewage and sludge.

Mixed sludge and sewage is decanted at the surface and separated into supernatant and sludge components.

The efficiency of deep shaft treatment can be high.

Surface aerators are commonly quoted as having an aeration efficiency of 0.5-1.5 kg O2/kWh, diffused aeration as 1.5-2.5 kg O2/KWh.

Deep Shaft claims 5-8 kg O2/kWh.

However, the costs of construction are high. Deep Shaft has seen greatest uptake in Japan, because of the land area issues.

Deep Shaft was developed by ICI, as a spin-off from their Pruteen process.

In the UK it is found at three sites: Tilbury, Anglian water, treating a wastewater with a high industrial contribution; Southport, United Utilities, because of land space issues; and Billingham, ICI, again treating industrial effluent, and built (after the Tilbury shafts) by ICI to help the agent sell more.

Deep Shaft is a patented, licensed, process. The licensee has changed several times and, currently (2007), it is Aker Kvaerner Engineering Services.

Surface-aerated basins

A Typical Surface-Aerated Basing (using motor-driven floating aerators)

Most biological oxidation processes for treating industrial wastewaters have in common the use of oxygen (or air) and microbial action.

Surface-aerated basins achieve 80 to 90% removal of BOD with retention times of 1 to 10 days. The basins may range in depth from 1.5 to 5.0 m and utilize motor-driven aerators floating on the surface of the wastewater.

In an aerated basin system, the aerators provide two functions: they transfer air into the basins required by the biological oxidation reactions, and they provide the mixing required for dispersing the air and for contacting the reactants (that is, oxygen, wastewater and microbes).

Typically, the floating surface aerators are rated to deliver the amount of air equivalent to 1.8 to 2.7 kg O2/kWh.

However, they do not provide as good mixing as is normally achieved in activated sludge systems and therefore aerated basins do not achieve the same performance level as activated sludge units.

Biological oxidation processes are sensitive to temperature and, between 0 °C and 40 °C, the rate of biological reactions increase with temperature.

Most surface aerated vessels operate at between 4 °C and 32 °C.

Aeration methods

Diffused Aeration

Sewage liquor is run into deep tanks with diffuser blocks attached to the floor. These are like the diffuser blocks used in tropical fish tanks but on a much larger scale.

Air is pumped through the blocks and the curtain of bubbles formed both oxygenates the liquor and also provide the necessary stirring action.

Where capacity is limited or the sewage is unusually strong or difficult to treat, oxygen may be used instead of air.

Typically, the air is generated by some type of blower or compressor. 

Surface aerators

Vertically mounted tubes of up to 1 m diameter extending from just above the base of a deep concrete tank to just below the surface of the sewage liquor.

A typical shaft might be 10 m high. At the surface end the tube is formed into a cone with helical vanes attached to the inner surface.

When the tube is rotated, the vanes spin liquor up and out of the cones drawing new sewage liquor from the base of the tank.

In many works each cone is located in a separate cell that can be isolated from the remaining cells if required for maintenance.

Some works may have two cones to a cell and some large works may have 4 cones per cell.

IWA Publishing spreads knowledge about our most valuable resource, water, helping to improve global health and well-being. We publish a portfolio of 17 peer reviewed journals and 800 books, along with other information resources. 

https://www.iwapublishing.com/news/activated-sludge-process

 




















Friday, September 13, 2019

WASTE WATER FLOW CAPACITY - In sewage piping and pumping systems, the flow velocity must exceed certain limits to maintain trouble free operation and to avoid settling and sedimentation of solids. On the other hand, the flow velocity should not exceed certain limits to avoid potential wear and tear due to erosion and abrasion.

Image result for images Waste Water - Flow Capacity
................................................................................................................
Image result for images Waste Water - Flow Capacity
Waste Water - Flow Capacity
The Engineering ToolBox




In sewage piping and pumping systems, the fluid flow rate must be kept within certain limits to avoid operating problems
In sewage piping and pumping systems, the flow velocity must exceed certain limits to maintain trouble free operation and to avoid settling and sedimentation of solids:
·          for horizontal wastewater pipe systems with solids the speed should exceed 3 ft/sec
·          for wastewater water system with organic solids the speed should exceed 2 ft/sec
On the other hand, the flow velocity should not exceed certain limits to avoid potential wear and tear due to erosion and abrasion:
·          the flow velocity in high-grit sewage handling systems should not exceed 12 ft/sec
·          the flow velocity in sewage systems with low grit concentrations should not exceed 18 ft/sec
Flow rate capacities in US gal for sewage piping and pumping systems within the limitations:
Flow Rate (US GPM) 
Pipe Dimension
(inches)
Minimum Velocity
Maximum Velocity
2 ft/sec
(0.6 m/s)
3 ft/sec
(0.9 m/s)
12 ft/sec
(3.6 m/s)
18 ft/sec
(5.4 m/s)
3
45
65
270
400
4
80
120
480
700
6
180
260
1050
1600
8
300
500
1900
2800
10
500
750
3000
4400
12
700
1100
4300
6400
Note! - based on clean pipes. The friction coefficient may vary with the pipe material.
·                     Unit Converter

About the ToolBox
We appreciate any comments and tips on how to make The Engineering ToolBox a better information source. Please contact us by email

Image result for images Waste Water - Flow Capacity

Saturday, July 20, 2019

HEAT EXCHANGERS - The classic example of a heat exchanger is found in an IC (Internal Combustion) Engine in which a circulating fluid known as engine coolant flows through radiator coils and air flows past the coils, which cools the coolant and heats the incoming air. Another example is the heat sink, which is a passive heat exchanger that transfers the heat generated by an electronic or a mechanical device to a fluid medium, often air or a liquid coolant. Heat is transferred by conduction through the exchanger materials which separate the mediums being used.

Heat Exchanger
...................................................................................................................................................
Heat Exchangers
What Is Heat Exchanger? Types Of Heat Exchangers
admin



A heat exchanger is a device designed to efficiently transfer or “exchange” heat from one matter to another (between a solid object and a fluid, or between two or more fluids).
When a fluid is used to transfer heat, the fluid could be a liquid, such as water or oil, or could be moving air.
The fluids may be separated by a solid wall to prevent mixing or they may be in direct contact.
Their applications includes:
1. Space heating
2. Refrigeration
3. Air conditioning
4. Power stations
5. Chemical plants
6. Petroleum refineries
7. Natural-gas processing
8. Sewage treatment
The classic example of a heat exchanger is found in an IC (Internal Combustion) Engine in which a circulating fluid known as engine coolant flows through radiator coils and air flows past the coils, which cools the coolant and heats the incoming air.
Another example is the heat sink, which is a passive heat exchanger that transfers the heat generated by an electronic or a mechanical device to a fluid medium, often air or a liquid coolant.
Heat is transferred by conduction through the exchanger materials which separate the mediums being used.
A shell and tube heat exchanger passes fluids through and over tubes, whereas an air-cooled heat exchanger passes cool air through a core of fins to cool a liquid.
There are various types of heat exchangers-
1.   Shell and tube heat exchanger
2.   Plate heat exchangers
3.   Plate and shell heat exchanger
4.   Adiabatic wheel heat exchanger
5.   Plate fin heat exchanger
6.   Pillow plate heat exchanger
7.   Fluid heat exchangers
8.   Waste heat recovery units. Dynamic scraped surface heat exchanger
9.   Phase-change heat exchangers
10. Direct contact heat exchangers
11. Micro-channel heat exchangers
Heat exchangers are commonly used for cooling of hot gasses and liquids, especially in industrial and manufacturing processes.
They can also be used to generate heat; for example, an Exhaust Gas Heat Exchanger can use the heat from exhaust gasses to heat up a water circuit, which can then be used around a building.
Heat Exchanger