Questions & Answers
part 3 - Does
my water require pretreatment before my UV?
Question: Does my water require pretreatment before my
UV?
Answer: Yes, you must have your
water tested prior to installing a UV systems. Many people feel that if they
can fill a glass with water and the water looks clear then that must mean that
it is.
This is not true. There is more to water
than what the naked eye can see. Water flowing through a UV system needs to be
free from hardness, iron, turbidity, manganese and color (which can be called
tannins).
If these levels are high, scaling can
occur, causing a decrease in the UV system's efficiency as well as an alarm
condition if the system is monitored.
We always recommend to our customers
that they install a 5 micron filter prior to the UV in order to knock down any
turbidity that may be present in the water.
We do recommend that if you are drawing
from a lake or from some other SURFACE water supply (lakes, rivers, dug well
etc.) that a water analysis is ALWAYS done prior to the installation of a UV.
Question: How do I disinfect water lines in my home?
Answer: A UV system is there to
protect your water from pathogenic microorganisms, BUT there is the potential
for harmful microorganisms to already be present in the water lines. The water
lines then need to be disinfected upon installation of the UV system.
A simple way to introduce a
disinfectant (chlorine) into the lines is via the filter. Once the Sterilight
system has been plumbed in simply remove the cartridge from the filter housing
and fill the housing halfway with household bleach (bleach contains 5.25%
chlorine).
With the Sterilight system ON, turn the
water on and ensure that at each and every tap a chlorine smell is detected.
Leave the bleach in the lines for at least one hour. Drain the chlorine from
the lines.
Question: What is a solenoid valve and can I hook one
up to a UV System?
Answer: A solenoid valve is an
electrically-activated mechanical valve that opens and closes when power is
applied to it. This kind of valve can be installed and wired into a Sterilight
system which is monitored.
If the UV intensity were to drop below
the recommended level the solenoid would then be activated and automatically
shut down the flow of water. This will keep contaminated water from getting
through the UV system.
A solenoid can be hooked up to a
Sterilight system either by dry contacts (the Platinum, SUV and SUVAM systems
all come equipped with dry contacts), or directly into the Sterilight system
(Silver and GOLD series can be hooked up directly to a solenoid; outside power
does NOT need to be brought to the solenoid).
Question: Where do I install UV in relation to other
treatment equipment?
Answer: The UV must be the
very LAST piece of water treatment equipment.
http://www.watertreatmentguide.com/ultraviolet_systems.htm
Click here for Part 1- Utraviolet Disinfection Systems
What
is UV light?
Click here for Part 2 - Utraviolet
Disinfection Systems
Will a UV system kill all microorganisms in my
water?
RELATED
POSTS:
..
.
.
CLICK HERE . . .
.
HYDROGEN
PEROXIDE
DISINFECTION
CLICK HERE . . .
Multi-Media Filter, Highly-Activated Carbon Filter,
Zeolite-Process Water Softener With Brine Tank,
Fiberglass Ballast-Type Pressure Tank
(fully automatic backwash & regeneration)
|
PURICARE
Water
Treatment
Systems
.
.
...
Aganan, Pavia, Iloilo, Philippines
...
CLICK HERE . . . to view company profile . . .
CLICK HERE . . . to view company profile . . .
No comments:
Post a Comment