WATER WELL PROBLEMS DUE TO BIOFOULING - Biofouling of a well is a form of biochemical incrustation that involves the creation of a continuous or discontinuous biofilms.


Biofouling of a Well

Written by Mr. Brian Oram, PG
Poor Water Quality, Reduced Well Yield, Slime Coatings or Microbiologically Induced Corrosion
Biofouling of a well is a form of biochemical incrustation that involves the creation of a continuous or discontinuous biofilms. 
A biofilm is defined as a “microbial growth occurring over a surface in which the individual cells are bound within a common extra cellular matrix of polymeric molecules.”
Biofouling is one of the five major causes for decreasing well yields and the development of poor well water quality, see Table 1. 
Table1. Bacteria in Groundwater And Influence on Water Quality
METABOLITE PROCESS
RESULT
Anaerobic

Fe (III) reducing  
Increased Dissolved Iron
Mn (IV) reducing 
Increase Dissolved Manganese
SO4 reducing
Produces S-2, hydrogen sulfide odors and FeS compounds
 Aerobic

Fe (II) Oxidizing
Convert soluble iron to iron oxides (precipitate or colloid)
Fe Precipitate
Deposits Fe(III) into biofilm
Mn (IV)
Deposit Mn into the biofilm
S-2 oxidizing
Form sulfurous slimes
Heterotrophs
Transform Carbon to CO2 - Increase Corrosion


                                              (Source: Method for Monitoring Fe and Mn, Biofouling in Water Wells, AWWA, 1992.) 
With respect to well yield, the “biofouling” creates a reduction of well yield, well efficiency, and poorer system performance. 
Just like chemical incrustation, the biofouling creates a “thick” discontinuous irregular layer of slimes and biofilms along the wellbore, well screen, piping/equipment, bedrock fractures, gravel pack, and within the aquifer
These films consist of a combination of amorphous polymeric chains containing metal oxides of iron, manganese, aluminum and other trace metals
These biofilms may also house or protect pathogenicbacteria, viruses, and protozoan.
Biofouling can cause the following to occur:
1) Decrease well yield and pump efficiency and ultimately pump failure;
2) Sudden changes in water quality that adversely impacts the taste, appearance, odor and chemical composition of the water;
3) Accelerated chemical and electrochemical corrosion that can result in increased metal content, aesthetic and taste problems, and failure of pumps and piping due to corrosion; and
4) Reduction in the strength of metal casings, well screens, and piping causing leaks and pipe failures.
Biofouling can influence the rate of chemical corrosion by producing organic/inorganic metabolites that can lower the pH, increase the concentration of hydrogen sulfide, and increase the ability of the fluid to carry a charge, and create differential “aeration” cells. 
The formation of these cells provides the mechanism for electrochemical corrosion or microbiologically induced corrosion (MIC) to occur.
Two conditions are needed for electrochemical corrosion to occur. 
These conditions include a difference in the electrical potential of the metal surfaces and a fluid that connects the materials that has a capacity to carry a charge. 
Electrochemical corrosion is more commonly associated with galvanic corrosion associated with the use of dissimilar metals, such as the corrosion associated with the connection of a copper pipe to a cast iron pipe. 
At the connection between the copper and cast iron pipe, a galvanic or electrical cell is formed. The copper pipe acts like a cathode and the cast iron acts like the anode. 
The cathode area is identified by the buildup or gain of ions and the anode area or pitted area is the loss of ions.
Tuberculation is the most typical form of corrosion. 
Tuberculations are knob like mounds of corrosion by-products that are found scattered over the surface of a corroding material. 
Microbiologically Induced Corrosion (MIC) has been recognized to be responsible for 10 to 30% of pipe corrosion and a major cause of tuberculation.
With respect to the health effects associated with biofilms, these films are normally considered non-pathogenic (i.e., not disease causing). 
For individuals that are immune-compromised these organisms may act as an “opportunistic pathogen”. 
In addition, these biofilms may accumulate trace metals (Fe, Mn, Al, Co, Ni, Cu, Zn, Cd, Sn) and provide a protected environment for pathogenic organisms to flourish. 
The slimy biofilms also provide a protective coating that limits the effectiveness of conventional disinfection practices. 
If the odor is stronger in the hot water, we recommend the following:
a. Turn off the system and drain.
b. Allow the tank to refill, but raise the temperature to a level above 140 F.
c. Allow the tank to be set at this level for at least 6 hours
d. Turn off the system and reduce to normal temperature.
e. Allow the tank to refill.


http://www.water-research.net/index.php/water-testing/private-well-testing/well-biofouling
RELATED POSTS: 
Using Chlorine to Fix 
Problematic Well Water
CLICK HERE . . .
.
Humic Substances:
humic acid, fulvic acid, and humin
CLICK HERE . . .
.
Disgusted residents find LIVE WORMS wriggling in their tap water
CLICK HERE . . .
http://puricare.blogspot.com/2016/05/parents-were-disgusted-to-know-they-had.html
.
Multi-Media Filter, Highly-Activated Carbon Filter,
Zeolite-Process Water Softener With Brine Tank,
Fiberglass Ballast-Type Pressure Tank
(fully automatic backwash & regeneration)
.
PURICARE 
INDUSTRIAL 
ENTERPRISES 
Water 
Treatment 
Systems
.
...
Aganan, Pavia, Iloilo, Philippines
...

CLICK HERE . . . to view company profile . . .
Reverse Osmosis with Steel Tank 
& Cartridge Pre-Filters

Submersible Pumps

Tachmina Solenoid-Driven
Chemical Metering Pump
- ensures regulated dosing
of chlorine into water system
without human intervention










No comments:

Post a Comment